eComo 04 LP
The eComo04 LP is the smallest processing unit in the eComo System assembly. It receives and processes signals from sensors, can show the real-time data on a small LCD display and send the information to our server, accesible from the user platform.
It is made entirely in Japan, with all electronic components from premium Japanese, American and European brands.
The housing is of high resistance plastic with IP66 protection, and can be installed outdoors and in any working environment. All inputs, outputs and external connections are through high quality waterproof metal connectors.
Specifications
Power Supply | ||
---|---|---|
Nominal Power CPU Consumption | 1 | W |
Power Consumption depending on the sensors | 2 ÷ 12 | W |
Power Supply mode | 12V battery /solar panel | |
Electric Distribution Power Supply | 12 | VDC |
Solar Panel Supply | 12 | VDC |
Nominal Current | 0,07 | A |
Peak Current | 1,0 | A |
Analog inputs | ||
Ports number | 4 | |
Sampling Frequency | 1 (max.) | Hz |
Maximun Input Voltage | ±6 / ±12 | VDC |
ADC Bit Depth | 24 | Bit |
Analog ports power supply* | ||
Output 12 VDC | ||
Maximun load current | 1 | A |
Ripple voltage level | 150 | mVp-p |
Output 9 VDC | ||
Maximun load current | 1 | A |
Ripple voltage level | 75 | mVp-p |
Output 6 VDC | ||
Maximun load current | 1 | A |
Ripple voltage level | 200 | mVp-p |
Output 5 VDC | ||
---|---|---|
Maximun load current | 1 | A |
Ripple voltage level | 250 | mVp-p |
Digital Inputs | ||
---|---|---|
Connectors | 4 | |
H level Voltage | 3,3 ÷ 12 | VDC |
L lever Voltage | 0 ÷ 1,2 | VDC |
Maximun input current | 9 | mA |
Additional Power supply | ||
Connectors | 4 | |
Voltage | 3.3/5/6/9/12 | VDC |
Maximun current * | 1 | A |
Ripple voltage | 150 | mVp-p |
LAN | ||
RJ 45 100BASE-TX/10BASE-T | 1 | |
Casing | ||
Dimensions | 295 x 225 x 150 | mm |
Weight | 2 | Kg |
Certifications | ||
CE / RoHS / EMC / WEEE | ||
Ambient conditions | ||
Operating temperature | -30 ÷ 70 | ºC |
Storage conditions | -40 ÷ 85 | ºC |
Humidity | 90%RH @ 60ºC | |
IP | 66 |